Inspection Report

Example Example

Property Address:
1234 Circle Road
Canton, OH 44706

Clevenger Home Inspection

Jon Clevenger
Jon@ClevengerHomeInspection.com
www.ClevengerHomeInspection.com
330-704-5887



Date: 9/24/2008Time: 4:45 PMReport ID: 120
Property:
1234 Circle Road
Canton, OH 44706
Customer:
Example Example
Real Estate Professional:

Comment Key or Definitions

The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.

Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.

Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.

Not Present (NP) = This item, component or unit is not in this home or building.

Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.

Age Of Home:
Under 10 Years

Client Is Present:
Yes

Radon Test:
No

Water Test:
No

Weather:
Clear

Temperature:
Over 65

Rain in last 3 days:
No




1. Roofing / Chimneys / Roof Structure and Attic

The home inspector shall observe: Roof covering; Roof drainage systems; Flashings; Skylights, chimneys, and roof penetrations; and Signs of' leaks or abnormal condensation on building components. The home inspector shall: Describe the type of roof covering materials; and Report the methods used to observe the roofing. The home inspector is not required to: Walk on the roofing; or Observe attached accessories including but not limited to solar systems, antennae, and lightning arrestors.

Styles & Materials
Viewed roof covering from:
Ground
Roof-Type:
Gable
Hip
Roof Covering:
3-Tab fiberglass
Roof Ventilation:
Ridge vents
Soffit Vents
Method used to observe attic:
Walked
Roof Structure:
Engineered wood trusses
Ceiling Structure:
2X4
Attic info:
Attic hatch
Attic Insulation:
Blown
Inspection Items
1.0 ROOF COVERINGS
Comments: Inspected
1.1 FLASHINGS
Comments: Inspected
1.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS
Comments: Inspected
1.3 ROOF VENTILATION
Comments: Inspected
1.4 ROOF DRAINAGE SYSTEMS (gutters and downspouts)
Comments: Repair or Replace
The downspout needs reconnecting to existing drain line at virtually all areas where gutters are installed. Erosion can continue or become worse if not corrected possibly leading to water intrusion. A qualified person should repair or replace as needed.
1.4 Picture 1
1.4 Picture 2
1.5 ROOF STRUCTURE AND ATTIC (Report leak signs or condensation)
Comments: Inspected
1.6 INSULATION IN ATTIC
Comments: Inspected
1.7 VISIBLE ELECTRIC WIRING IN ATTIC
Comments: Inspected
The roof of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Roof coverings and skylights can appear to be leak proof during inspection and weather conditions. Our inspection makes an attempt to find a leak but sometimes cannot. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.



2. Exterior

The home inspector shall observe: Wall cladding, flashings, and trim; Entryway doors and a representative number of windows; Garage door operators; Decks, balconies, stoops, steps, areaways, porches and applicable railings; Eaves, soffits, and fascias; and Vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The home inspector shall: Describe wall cladding materials; Operate all entryway doors and a representative number of windows; Operate garage doors manually or by using permanently installed controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meeting reasonable resistance during closing; and Probe exterior wood components where deterioration is suspected. The home inspector is not required to observe: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Fences; Presence of safety glazing in doors and windows; Garage door operator remote control transmitters; Geological conditions; Soil conditions; Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detached buildings or structures; or Presence or condition of buried fuel storage tanks. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility.

Styles & Materials
Siding Material:
Vinyl
Exterior Entry Doors:
Steel
Appurtenance:
Covered porch
Driveway:
Concrete
Inspection Items
2.0 WALL CLADDING FLASHING AND TRIM
Comments: Repair or Replace
The Vinyl siding at the rear of home is damaged. Deterioration can occur if not corrected. A qualified contractor should inspect and repair as needed.
2.0 Picture 1
2.1 DOORS (Exterior)
Comments: Repair or Replace
(1) The basement entry door does not lock. This is considered unsafe and needs correcting. A qualified contractor should inspect and repair as needed.
(2) The screen door at the rear of home has a damaged screen. A repair or replacement is needed. A qualified person should repair or replace as needed.
2.1 Picture 1
(3) The garage side entry door shows areas of peeling paint. This is a maintenance issue and is for your information. A qualified person should repair or replace as needed.
2.1 Picture 2
2.2 WINDOWS
Comments: Inspected
2.3 DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS
Comments: Inspected
2.4 VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIO FLOOR, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building)
Comments: Repair or Replace
The concrete drive at the front of home has dropped or settled causing a steep or uneven step. A fall or injury can occur if not corrected and A general replacement is likely. A qualified contractor should inspect and repair as needed.
2.4 Picture 1
2.4 Picture 2
2.5 EAVES, SOFFITS AND FASCIAS
Comments: Inspected
2.6 PLUMBING WATER FAUCETS (hose bibs)
Comments: Inspected
2.7 OUTLETS (exterior)
Comments: Inspected
The exterior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.



3. Garage

Styles & Materials
Garage Door Type:
One automatic
Garage Door Material:
Insulated
Metal
Auto-opener Manufacturer:
SEARS
Inspection Items
3.0 GARAGE CEILINGS
Comments: Inspected
3.1 GARAGE WALLS (INCLUDING FIREWALL SEPARATION)
Comments: Inspected
3.2 GARAGE FLOOR
Comments: Inspected
3.3 GARAGE DOOR (S)
Comments: Inspected
3.4 OCCUPANT DOOR FROM GARAGE TO INSIDE HOME
Comments: Inspected
3.5 GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance)
Comments: Repair or Replace
Safety reverse by photoelectric eyes were not present or were not working properly. Recommend repair or replacement.
3.5 Picture 1



4. Kitchen Components and Appliances

The home inspector shall observe and operate the basic functions of the following kitchen appliances: Permanently installed dishwasher, through its normal cycle; Range, cook top, and permanently installed oven; Trash compactor; Garbage disposal; Ventilation equipment or range hood; and Permanently installed microwave oven. The home inspector is not required to observe: Clocks, timers, self-cleaning oven function, or thermostats for calibration or automatic operation; Non built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable.

Styles & Materials
Exhaust/Range hood:
BROAN
Cabinetry:
Wood
Countertop:
Laminate
Clothes Dryer Vent Material:
Flexible Metal
Dryer Power Source:
220 Electric
Inspection Items
4.0 CEILINGS
Comments: Inspected
4.1 WALLS
Comments: Inspected
4.2 FLOORS
Comments: Inspected
4.3 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Comments: Inspected
4.4 PLUMBING DRAIN AND VENT SYSTEMS
Comments: Inspected
4.5 PLUMBING WATER SUPPLY FAUCETS AND FIXTURES
Comments: Repair or Replace
The lever on faucet leaks at the kitchen sink. Repairs are needed to stop leaking water from damaging the cabinet bottom or to eliminate moisture that may contribute to fungi growth. I recommend repair as necessary by a qualified person.
4.5 Picture 1
4.6 OUTLETS WALL SWITCHES and FIXTURES
Comments: Inspected
4.7 DISHWASHER
Comments: Not Present
4.8 RANGES/OVENS/COOKTOPS
Comments: Not Present
4.9 RANGE HOOD
Comments: Inspected
4.10 FOOD WASTE DISPOSER
Comments: Inspected
4.11 CLOTHES DRYER VENT PIPING
Comments: Inspected
The built-in appliances of the home were inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.



5(A). Living Room

The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.

Styles & Materials
Ceiling Materials:
Drywall
Wall Material:
Drywall
Floor Covering(s):
Carpet
Laminated T&G
Tile
Interior Doors:
Hollow core
Raised panel
Window Types:
Double-hung
Inspection Items
5.0.A CEILINGS
Comments: Inspected
5.1.A WALLS
Comments: Inspected
5.2.A FLOORS
Comments: Inspected
5.3.A STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Comments: Inspected
5.4.A DOORS (REPRESENTATIVE NUMBER)
Comments: Inspected
5.5.A WINDOWS (REPRESENTATIVE NUMBER)
Comments: Inspected
5.6.A OUTLETS SWITCHES AND FIXTURES
Comments: Inspected
The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.



5(B). Bedrooms

The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.

Styles & Materials
Ceiling Materials:
Drywall
Wall Material:
Drywall
Floor Covering(s):
Carpet
Interior Doors:
Hollow core
Raised panel
Window Types:
Double-hung
Inspection Items
5.0.B CEILINGS
Comments: Inspected
5.1.B WALLS
Comments: Inspected
5.2.B FLOORS
Comments: Inspected
5.3.B DOORS (REPRESENTATIVE NUMBER)
Comments: Inspected
5.4.B WINDOWS (REPRESENTATIVE NUMBER)
Comments: Inspected
5.5.B OUTLETS SWITCHES AND FIXTURES
Comments: Inspected
The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.



5(C). Dining Room

The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.

Styles & Materials
Ceiling Materials:
Drywall
Wall Material:
Drywall
Floor Covering(s):
Laminated T&G
Window Types:
Double-hung
Inspection Items
5.0.C CEILINGS
Comments: Inspected
5.1.C WALLS
Comments: Inspected
5.2.C FLOORS
Comments: Inspected
5.3.C WINDOWS (REPRESENTATIVE NUMBER)
Comments: Inspected
5.4.C OUTLETS SWITCHES AND FIXTURES
Comments: Inspected
The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.



5(D). Hallway and Other Rooms

The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.

Styles & Materials
Ceiling Materials:
Drywall
Wall Material:
Drywall
Floor Covering(s):
Laminated T&G
Interior Doors:
Hollow core
Wood
Inspection Items
5.0.D CEILINGS
Comments: Inspected
5.1.D WALLS
Comments: Inspected, Repair or Replace
The sheetrock on the wall is damaged at the Living Room and hallway. This damage is considered cosmetic. A qualified person should repair or replace as needed.
5.1.D Picture 1
5.2.D FLOORS
Comments: Inspected
5.3.D STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Comments: Inspected
5.4.D DOORS (REPRESENTATIVE NUMBER)
Comments: Inspected
5.5.D OUTLETS SWITCHES AND FIXTURES
Comments: Inspected
The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.



6(A). Hall Bath

Styles & Materials
Exhaust Fans:
Fan with light
Inspection Items
6.0.A COUNTERS AND CABINETS
Comments: Inspected
6.1.A DOORS (REPRESENTATIVE NUMBER)
Comments: Inspected
6.2.A PLUMBING DRAIN, WASTE AND VENT SYSTEMS
Comments: Inspected
6.3.A PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments: Inspected
6.4.A OUTLETS SWITCHES AND FIXTURES
Comments: Inspected
6.5.A EXHAUST FAN
Comments: Inspected



6(B). Master Bath

Styles & Materials
Exhaust Fans:
Fan with light
Inspection Items
6.0.B COUNTERS AND CABINETS
Comments: Inspected
6.1.B DOORS (REPRESENTATIVE NUMBER)
Comments: Inspected
6.2.B PLUMBING DRAIN, WASTE AND VENT SYSTEMS
Comments: Inspected
6.3.B PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments: Inspected
6.4.B OUTLETS SWITCHES AND FIXTURES
Comments: Inspected
6.5.B EXHAUST FAN
Comments: Inspected



6(C). 1/2 Bath

Styles & Materials
Exhaust Fans:
None
Inspection Items
6.0.C COUNTERS AND CABINETS
Comments: Inspected
6.1.C DOORS (REPRESENTATIVE NUMBER)
Comments: Inspected
6.2.C PLUMBING DRAIN, WASTE AND VENT SYSTEMS
Comments: Inspected
6.3.C PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments: Inspected
The tub faucets and shower head is loose at the lower level bath. Repairs are needed. I recommend a licensed plumber inspect further and repair as necessary.
6.3.C Picture 1
6.4.C OUTLETS SWITCHES AND FIXTURES
Comments: Inspected



7. Structural Components

The Home Inspector shall observe structural components including foundations, floors, walls, columns or piers, ceilings and roof. The home inspector shall describe the type of Foundation, floor structure, wall structure, columns or piers, ceiling structure, roof structure. The home inspector shall: Probe structural components where deterioration is suspected; Enter under floor crawl spaces, basements, and attic spaces except when access is obstructed, when entry could damage the property, or when dangerous or adverse situations are suspected; Report the methods used to observe under floor crawl spaces and attics; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to: Enter any area or perform any procedure that may damage the property or its components or be dangerous to or adversely effect the health of the home inspector or other persons.

Styles & Materials
Foundation:
Masonry block
Floor Structure:
2 X 10
Wood joists
Wall Structure:
2 X 4 Wood
Inspection Items
7.0 FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.)
Comments: Repair or Replace
Visible signs of water intrusion in the basement (along front of home) are present from water stains along the block wall. Water intrusion if not corrected can lead to other problems including mold and cause excessive moisture to floor system that can lead to deterioration and increased repair cost.. I recommend further investigation or correction by a qualified licensed contractor or water infiltration specialist.
7.1 WALLS (Structural)
Comments: Inspected
7.2 FLOORS (Structural)
Comments: Inspected
7.3 CEILINGS (structural)
Comments: Inspected
Most of the walls and ceilings in the finished basement are covered and structural members are not visible. No obvious problems discovered. I could not see behind these coverings.
The structure of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.



8. Plumbing System

The home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps. The home inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance. The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials.

Styles & Materials
Water Source:
Public
Plumbing Water Supply (into home):
Copper
Plumbing Water Distribution (inside home):
Copper
Washer Drain Size:
2" Diameter
Plumbing Waste Line:
PVC
Water Heater Power Source:
Gas (quick recovery)
Water Heater Capacity:
40 Gallon (1-2 people)
Inspection Items
8.0 PLUMBING DRAIN, WASTE AND VENT SYSTEMS
Comments: Inspected
8.1 PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments: Inspected
8.2 HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS
Comments: Inspected
8.3 MAIN WATER SHUT-OFF DEVICE (Describe location)
Comments: Inspected
The main shut off is the lever located in the basement. This is for your information.
8.4 FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks)
Comments: Inspected
8.5 MAIN FUEL SHUT OFF (Describe Location)
Comments: Inspected
The main fuel shut off is at gas meter outside
The plumbing in the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Washing machine drain line for example cannot be checked for leaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed and barely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waiting for closing) rust or deposits within the pipes can further clog the piping system. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.



9. Electrical System

The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main over current device, and main and distribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their over current devices, and the compatibility of their ampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smoke detectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead or underground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The home inspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of a central system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over current device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment.

Styles & Materials
Electrical Service Conductors:
Overhead service
Panel capacity:
200 AMP
Panel Type:
Circuit breakers
Branch wire 15 and 20 AMP:
Copper
Wiring Methods:
Romex
Inspection Items
9.0 SERVICE ENTRANCE CONDUCTORS
Comments: Inspected
9.1 SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS
Comments: Inspected
9.2 BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE
Comments: Inspected
9.3 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments: Inspected
9.4 POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE
Comments: Inspected
9.5 OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)
Comments: Inspected
9.6 LOCATION OF MAIN AND DISTRIBUTION PANELS
Comments: Inspected
The main panel box is located at the basement.
9.7 SMOKE DETECTORS
Comments: Inspected
The electrical system of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Outlets were not removed and the inspection was only visual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.



10. Heating / Central Air Conditioning

The home inspector shall observe permanently installed heating and cooling systems including: Heating equipment; Cooling Equipment that is central to home; Normal operating controls; Automatic safety controls; Chimneys, flues, and vents, where readily visible; Solid fuel heating devices; Heat distribution systems including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units, convectors; and the presence of an installed heat source in each room. The home inspector shall describe: Energy source; and Heating equipment and distribution type. The home inspector shall operate the systems using normal operating controls. The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate heating systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections; Humidifiers; Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms.

Styles & Materials
Heat Type:
Forced Air
Energy Source:
Gas
Number of Heat Systems (excluding wood):
One
Ductwork:
Non-insulated
Filter Type:
Disposable
Cooling Equipment Type:
Air conditioner unit
Cooling Equipment Energy Source:
Electricity
Inspection Items
10.0 HEATING EQUIPMENT
Comments: Inspected
10.1 NORMAL OPERATING CONTROLS
Comments: Inspected
10.2 AUTOMATIC SAFETY CONTROLS
Comments: Inspected
10.3 DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments: Inspected
10.4 PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM
Comments: Inspected
10.5 CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems)
Comments: Inspected
10.6 COOLING AND AIR HANDLER EQUIPMENT
Comments: Inspected, Repair or Replace
The platform for the air conditioner is not level. This can cause damage to the unit or shorten its life span. Suggest leveling platform or unit.
10.6 Picture 1
10.7 NORMAL OPERATING CONTROLS
Comments: Inspected
10.8 PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM
Comments: Inspected
The heating and cooling system of this home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed heat contractor would discover. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

Prepared Using HomeGauge
http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To Clevenger Home Inspection



General Summary


Clevenger Home Inspection

Jon@ClevengerHomeInspection.com
www.ClevengerHomeInspection.com
330-704-5887

Customer
Example Example

Property Address
1234 Circle Road
Canton, OH 44706

The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

1. Roofing / Chimneys / Roof Structure and Attic
1.4 ROOF DRAINAGE SYSTEMS (gutters and downspouts)
 Repair or Replace
The downspout needs reconnecting to existing drain line at virtually all areas where gutters are installed. Erosion can continue or become worse if not corrected possibly leading to water intrusion. A qualified person should repair or replace as needed.

2. Exterior
2.0 WALL CLADDING FLASHING AND TRIM
 Repair or Replace
The Vinyl siding at the rear of home is damaged. Deterioration can occur if not corrected. A qualified contractor should inspect and repair as needed.
2.1 DOORS (Exterior)
 Repair or Replace
(1) The basement entry door does not lock. This is considered unsafe and needs correcting. A qualified contractor should inspect and repair as needed.
(2) The screen door at the rear of home has a damaged screen. A repair or replacement is needed. A qualified person should repair or replace as needed.
(3) The garage side entry door shows areas of peeling paint. This is a maintenance issue and is for your information. A qualified person should repair or replace as needed.
2.4 VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIO FLOOR, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building)
 Repair or Replace
The concrete drive at the front of home has dropped or settled causing a steep or uneven step. A fall or injury can occur if not corrected and A general replacement is likely. A qualified contractor should inspect and repair as needed.

3. Garage
3.5 GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance)
 Repair or Replace
Safety reverse by photoelectric eyes were not present or were not working properly. Recommend repair or replacement.

4. Kitchen Components and Appliances
4.5 PLUMBING WATER SUPPLY FAUCETS AND FIXTURES
 Repair or Replace
The lever on faucet leaks at the kitchen sink. Repairs are needed to stop leaking water from damaging the cabinet bottom or to eliminate moisture that may contribute to fungi growth. I recommend repair as necessary by a qualified person.

5(D). Hallway and Other Rooms
5.1.D WALLS
 Inspected, Repair or Replace
The sheetrock on the wall is damaged at the Living Room and hallway. This damage is considered cosmetic. A qualified person should repair or replace as needed.

7. Structural Components
7.0 FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.)
 Repair or Replace
Visible signs of water intrusion in the basement (along front of home) are present from water stains along the block wall. Water intrusion if not corrected can lead to other problems including mold and cause excessive moisture to floor system that can lead to deterioration and increased repair cost.. I recommend further investigation or correction by a qualified licensed contractor or water infiltration specialist.

10. Heating / Central Air Conditioning
10.6 COOLING AND AIR HANDLER EQUIPMENT
 Inspected, Repair or Replace
The platform for the air conditioner is not level. This can cause damage to the unit or shorten its life span. Suggest leveling platform or unit.


Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To Clevenger Home Inspection